55 Results for Wire Connectors & Disconnects by SOUTHWIRE
Brand
SOUTHWIRE
Mfr # 68580023
Key Features:
- Standards: Standards & ReferencesSouthwire Armorlite® Type MC Cable meets or exceeds the requirements of the following:UL 83UL 1569UL 1685UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )Federal Specification A-A59544 (formerly J-C-30B)FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame TestNFPA 70 (National Electrical Code), Article 330Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop SystemsREACH/RoHS-2 (Chemical Limit) Compliant
- Insulation Thickness (Mils): 15mils
- Size (Awg or Kcmil): 12 AWG
Mfr # PTST12BK
Key Features:
- Height: 0.13
- Width: 0.13
- Length: 8
Mfr # 68580021
Key Features:
- Standards: Standards & ReferencesSouthwire Armorlite® Type MC Cable meets or exceeds the requirements of the following:UL 83UL 1569UL 1685UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )Federal Specification A-A59544 (formerly J-C-30B)FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame TestNFPA 70 (National Electrical Code), Article 330Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop SystemsREACH/RoHS-2 (Chemical Limit) Compliant
- Size (Awg or Kcmil): 12 AWG
- No. of Strands: 1
Mfr # 68579221
Key Features:
- Standards: Standards & ReferencesSouthwire Armorlite® Type MC Cable meets or exceeds the requirements of the following:UL 83UL 1569UL 1685UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )Federal Specification A-A59544 (formerly J-C-30B)FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame TestNFPA 70 (National Electrical Code), Article 330Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop SystemsREACH/RoHS-2 (Chemical Limit) Compliant
- Nom. Od (Mils): 451mils
- No. of Strands: 1
Mfr # 68580021
Key Features:
- Standards: Standards & ReferencesSouthwire Armorlite® Type MC Cable meets or exceeds the requirements of the following:UL 83UL 1569UL 1685UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )Federal Specification A-A59544 (formerly J-C-30B)FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame TestNFPA 70 (National Electrical Code), Article 330Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop SystemsREACH/RoHS-2 (Chemical Limit) Compliant
- No. of Conductors: 2
- No. of Strands: 1
Mfr # 68579221
Key Features:
- Standards: Standards & ReferencesSouthwire Armorlite® Type MC Cable meets or exceeds the requirements of the following:UL 83UL 1569UL 1685UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )Federal Specification A-A59544 (formerly J-C-30B)FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame TestNFPA 70 (National Electrical Code), Article 330Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop SystemsREACH/RoHS-2 (Chemical Limit) Compliant
- Nom. Od (Mils): 451mils
- Applications: ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.