Item
|
UPS System
|
VA Rating - UPS Systems
|
330.0 VA
|
UPS Type
|
Line Interactive
|
Power Rating
|
330VA
|
Watts - UPS Systems
|
225.0 W
|
Mounting
|
Tower/Wall
|
Input Voltage - UPS Systems
|
120V AC
|
Output Voltage - UPS Systems
|
120V AC
|
Wattage
|
225 W
|
Input Voltage
|
120V AC
|
Output Voltage
|
120V AC
|
Backup Time (Half/Full Load)
|
46 min/18 min
|
Outlet Type - UPS Systems
|
UPS/Surge
|
Outlet Type
|
UPS/Surge
|
Medical Grade
|
Yes
|
Number of Outlets
|
4
|
Green Environmental Attribute
|
Product Contributes To Reducing Energy Consumption
|
Special Features
|
Poweralert Software, Voltage Regulation
|
Automatic Volts Regulation
|
Yes
|
Watts
|
225W
|
Display Type
|
LED
|
NEMA Plug Configuration
|
5-15p
|
NEMA Receptacle Configuration
|
5-15R
|
Fax/Modem Line Protection
|
Yes
|
Input Current
|
2.3 A
|
Phase
|
1
|
Includes
|
Serial Cable for Remote Monitoring
|
Ports
|
DB9 Serial
|
Mounting - UPS Systems
|
Tower/Wall
|
Hz
|
60 Hz
|
Transfer Time
|
2 to 4 msec
|
Standards
|
UL 1778; CSA; FCC Part 15 Category B (EMI); UL60601-1 (medical grade)
|
Footnotes
|
3,6,14
|
Green Certification or Other Recognition
|
UL1778 (USA, Series AGOM350KSR57HG), UL2601-1 (Medical), cUL (Canada), FCC Class B (emissions), FCC Part 68 / Industry of Canada (telecommunications), Conforms to IEEE 587 / ANSI C62.41 specifications
|
Capacity - Batteries
|
330 VA/225 W
|
Operating Temp. Range
|
104°F (40°C)
|
Backup/Run Time (Full Load)
|
18 Minute/46 Minute
|
Battery Type
|
Sealed Lead Acid (SLA)
|
Input Connection
|
6 ft Cord with NEMA 5-15P-HG Plug
|
Output Volt Amp Capacity (VA)
|
330
|
UPS Input Connection Type
|
5-15P-HG
|
Output Receptacle Details
|
Hospital grade output receptacles
|
AC Mode BTU / Hr. (Full Load)
|
48.8
|
Frequency Compatibility
|
60 Hz
|
Battery Recharge Rate (Included Batteries)
|
Less than 4.5 hours from 10% to 90%
|
Battery Mode BTU / Hr. (Full Load)
|
215.8
|
Primary Form Factor
|
Tower
|
Internal UPS Replacement Battery Cartridge
|
RBC52 (quantity 2)
|
Recommended Electrical Service
|
15A 120V
|
UPS Dataline Suppression
|
2 line TEL/DSL
|
Alarm Cancel Operation
|
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
Output AC Waveform (Battery Mode)
|
PWM sine wave
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
|
Expandable Runtime
|
No
|
Nominal Input Voltage(s) Supported
|
120V AC
|
UPS AC Suppression Response Time
|
Instantaneous
|
Output Watt Capacity (Watts)
|
225
|
Installation Form Factors Supported with Optional Accessories
|
Wallmount (UPSWM - tower mounting kit)
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
|
Output Receptacles
|
(4) 5-15R
|
DC System Voltage (VDC)
|
12
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Communications Cable
|
DB9 serial cable included
|
High Availability UPS Features
|
Hot swappable batteries
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
Low Voltage Transfer to Battery Power (Setpoint)
|
89
|
Input Phase
|
Single-Phase
|
Relative Humidity
|
0 to 95%, non-condensing
|
Audible Alarm
|
Audible alarm indicates power-failure and low-battery conditions
|
UPS Housing Material
|
PVC
|
AC Mode Efficiency Rating (100% Load)
|
0.94
|
EMI / RFI AC Noise Suppression
|
Yes
|
Output Voltage Regulation (Line Mode)
|
-18%, +8%
|
High Voltage Transfer to Battery Power (Setpoint)
|
139
|
Battery Access
|
Battery access door
|
Half Load Runtime (min.)
|
46 min. (115w)
|
Battery Replacement Description
|
Hot-swappable, user replaceable batteries
|
LED Indicators
|
4 LEDs indicate line power, battery power, overload and battery low/replace status
|
Communications Interface
|
DB9 Serial
|
Installation Form Factors Supported with Included Accessories
|
Tower
|
Switches
|
2 Switches control off/on power status and alarm-cancel/self-test operation
|
Full Load Runtime (min.)
|
18 min. (225w)
|
Input Circuit Breakers
|
3.5A
|
Individually Controllable Load Banks
|
No
|
Undervoltage Correction
|
Input voltages between 89 and 107 are boosted by 14%
|
UPS Certifications
|
Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); Tested to UL60601-1 (medical grade)
|
Rated input current (Maximum Load)
|
2.3A
|
Output Isolation Transformer
|
Hospital grade load isolation transformer
|
Grounding Lug
|
Grounding lug
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
Nominal Output Voltage(s) Supported
|
120V
|
Output AC Waveform (AC Mode)
|
Sine wave
|
Package Contents
|
OmniSmart 350HG UPS, OMNI SMART 350HG Hospital Grade UPS System, Serial cable for remote monitoring, Warranty information, Instruction manual
|
Typical Battery Recharge Time
|
4 Hour
|
Certifications & Standards
|
UL1778 (USA, Series AGOM350KSR57HG), UL2601-1 (Medical), cUL (Canada), FCC Class B (emissions), FCC Part 68 / Industry of Canada (telecommunications), Conforms to IEEE 587 / ANSI C62.41 specifications
|
Product Type
|
Line-interactive UPS
|
Form Factor
|
Tower
|
Product Line
|
OmniSmart
|
Battery Chemistry
|
Lead Acid
|
Load Capacity
|
330 VA/225 W
|
Receptacle Detail
|
4 x NEMA 5-15R
|
Additional Information
|
Ideal UPS protection for applications in medical patient-care areas where UL2601-1 listed electrical medical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation prevents shock potential and operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 330VA / 225 watts, 46 minutes half load runtime (with 165VAload), 18 minutes full load runtime (with 330VA load), 4 protected hospital-grade outlets; 6-ft. cord, 1-DB9 serial port for network interface; SNMP compatible, Complete surge protection, line isolation and EMI/RFI noise filtering, 2 phone line surge suppression for modems, fax machines and other phone accessories, 2 year product warranty, Complete remote monitoring cabling included, PowerAlert UPS managment software available via free download, 4 diagnostic LEDs indicate AC present, on battery, voltage correction & battery low/replace, Battery replacement door, Grounding lug
|
Network Management
|
SNMP Manageable
|
Plug/Connector Type
|
NEMA 5-15P
|
Battery Life
|
6 Year
|
Status Indicators
|
Includes 4 front-panel status indicator LEDs for line power, battery power, voltage regulation and battery low/replace status
|
Product Name
|
OmniSmart 350HG UPS
|
Backup/Run Time (Half Load)
|
46 Minute
|
Alarm
|
On Battery
|
Maximum Operating Temperature
|
104°F (40°C)
|
Product Compliance
|
FCC Part 15 Class B (USA)
|
Grounding Details
|
Grounding lug
|
Package Includes
|
OMNI SMART 350HG Hospital Grade UPS System;Serial cable for remote monitoring;Warranty information;Instruction manual
|
Product Certifications
|
CSA (Canada); UL 1778; UL 60601-1
|
Output Capacity (VA)
|
330
|
UPS Applications
|
Hospital/Medical
|
Battery Mode Heat Dissipation (BTU/Hr) @ Half Load
|
78.3
|
Runtime Full Load (min.)
|
18 min. (225W)
|
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
|
215.8
|
Runtime Half Load (min.)
|
46 min. (113W)
|
Output Capacity (Watts)
|
225
|