Item
|
UPS System
|
UPS Type
|
Line Interactive
|
VA Rating - UPS Systems
|
1.5 kVA
|
Watts - UPS Systems
|
980.0 W
|
Power Rating
|
1.5kVA
|
Mounting
|
Tower/Wall
|
Input Voltage - UPS Systems
|
120V AC
|
Output Voltage - UPS Systems
|
120V AC
|
Wattage
|
980 W
|
Input Voltage
|
120V AC
|
Output Voltage
|
110/115/120V
|
Outlet Type - UPS Systems
|
UPS/Surge
|
Backup Time (Half/Full Load)
|
20 min/7 min
|
Outlet Type
|
UPS/Surge
|
Medical Grade
|
No
|
Number of Outlets
|
6
|
Display Type
|
LED
|
Footnotes
|
USB and RS232
|
Hz
|
60 Hz
|
Watts
|
980W
|
NEMA Receptacle Configuration
|
5-15R
|
Green Environmental Attribute
|
Product Contributes To Reducing Energy Consumption
|
Automatic Volts Regulation
|
Yes
|
Mounting - UPS Systems
|
Tower/Wall
|
NEMA Plug Configuration
|
5-15p
|
Transfer Time
|
2 to 4 msec
|
Input Current
|
12 A
|
Standards
|
UL 1778
|
Special Features
|
Hot Swappable Batteries
|
Fax/Modem Line Protection
|
No
|
Includes
|
PowerAlert Unattended Shutdown and UPS/Power Monitoring Software, USB and DB9 Monitoring Cables
|
Ports
|
RS232, USB
|
Phase
|
1
|
Green Certification or Other Recognition
|
UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications
|
Capacity - Batteries
|
1500 VA/980 W
|
Operating Temp. Range
|
122°F (50°C)
|
Housing Color
|
Black
|
Backup/Run Time (Full Load)
|
7 Minute/20 Minute
|
Battery Type
|
Sealed Lead Acid (SLA)
|
Input Connection
|
NEMA 5-15P Plug
|
Load Management Receptacles
|
One switchable single-outlet 5-15R load bank
|
EMI / RFI AC Noise Suppression
|
Yes
|
AC Mode Efficiency Rating (100% Load)
|
0.96
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Undervoltage Correction
|
Input voltages between 93 and 107 are boosted by 14%
|
Individually Controllable Load Banks
|
Yes
|
Communications Interface
|
USB; DB9 Serial
|
Switches
|
2 Switches control off/on power status and alarm-cancel/self-test operation
|
Output Watt Capacity (Watts)
|
980
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
Installation Form Factors Supported with Included Accessories
|
Tower
|
UPS Input Connection Type
|
5-15P
|
Relative Humidity
|
0 to 95%, non-condensing
|
Primary Form Factor
|
Tower
|
Nominal Input Voltage(s) Supported
|
120V AC
|
Output Volt Amp Capacity (VA)
|
1500
|
Output Receptacles
|
(6) 5-15R
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
Battery Access
|
Battery access door
|
UPS Housing Material
|
PVC
|
Audible Alarm
|
Audible alarm indicates power-failure, overload and low-battery conditions
|
Full Load Runtime (min.)
|
7 min. (980w)
|
Battery Replacement Description
|
Hot-swappable, user replaceable batteries
|
Communications Cable
|
USB and DB9 cabling included
|
Battery Mode BTU / Hr. (Full Load)
|
456
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
UPS AC Suppression Joule Rating
|
510
|
Rated input current (Maximum Load)
|
12A
|
Nominal Voltage Details
|
120v nominal output in battery mode
|
AC Mode BTU / Hr. (Full Load)
|
139
|
UPS Certifications
|
Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
|
Low Voltage Transfer to Battery Power (Setpoint)
|
75
|
Output kVA Capacity (kVA)
|
1.5
|
UPS AC Suppression Response Time
|
Instantaneous
|
Battery Recharge Rate (Included Batteries)
|
Less than 4 hours from 10% to 90% (typical, full load discharge)
|
High Availability UPS Features
|
Hot swappable batteries
|
Half Load Runtime (min.)
|
20 min. (490w)
|
Overvoltage Correction
|
Input voltages between 128 and 147 are reduced by 12%
|
Output Voltage Regulation (Line Mode)
|
-18%, +8%
|
Output AC Waveform (Battery Mode)
|
PWM sine wave
|
Internal UPS Replacement Battery Cartridge
|
RBC36-SLT
|
Recommended Electrical Service
|
15A 120V
|
UPS Certification Details
|
UL1778 2ND Edition; CAN/CSA No.0-M1982, 0.4-M1982, 107.1-M91 and 601.1
|
Frequency Compatibility
|
60 Hz
|
Cooling Method
|
Fan
|
WatchDog Compatibility
|
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Input Phase
|
Single-Phase
|
Severe Undervoltage Correction
|
Input voltages between 75 and 92 are boosted by 30%
|
Network Monitoring Port Description
|
Supports detailed monitoring of UPS and site power conditions
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
|
Input Circuit Breakers
|
15A
|
DC System Voltage (VDC)
|
36
|
Installation Form Factors Supported with Optional Accessories
|
Wallmount (UPSWM - tower mounting kit)
|
Output AC Waveform (AC Mode)
|
Sine wave
|
High Voltage Transfer to Battery Power (Setpoint)
|
147
|
Alarm Cancel Operation
|
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
|
LED Indicators
|
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
Expandable Runtime
|
No
|
Product Color
|
Black
|
Product Name
|
SmartPro 1500VA UPS
|
Plug/Connector Type
|
NEMA 5-15P
|
Hot Swappable
|
Yes
|
Certifications & Standards
|
UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications
|
Battery Chemistry
|
Lead Acid
|
Surge Energy Rating
|
480 J
|
Receptacle Detail
|
6 x NEMA 5-15R
|
Protection Type
|
Black Out, Brownout, Over Voltage, Surge
|
Total Number of Expansion Slots
|
3
|
Network Management
|
SNMP Manageable
|
Product Type
|
Line-interactive UPS
|
Package Contents
|
UPS System, USB and DB9 monitoring cables, PowerAlert unattended shutdown and UPS/Power monitoring software CD, Instruction manual with warranty information
|
Maximum Operating Temperature
|
122°F (50°C)
|
Status Indicators
|
Includes 5 front panel LEDs to indicate BATTERY CHARGE LEVEL, AC LINE POWER STATUS, VOLTAGE REGULATION STATUS, UPS LOAD LEVEL and BATTERY LOW / REPLACE information
|
Typical Battery Recharge Time
|
4 Hour
|
USB
|
Yes
|
Software Included
|
PowerAlert Software
|
Product Line
|
SmartPro
|
Alarm
|
Low Battery, On Battery, Overload
|
Backup/Run Time (Half Load)
|
20 Minute
|
Battery Life
|
6 Year
|
Form Factor
|
Tower
|
Load Capacity
|
1500 VA/980 W
|
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
|
456
|
Runtime Half Load (min.)
|
20 min. (490W)
|
Output Capacity (VA)
|
1500
|
Product Compliance
|
FCC Part 15 Class A (USA)
|
Package Includes
|
SMART1500 SmartPro 120V 1.5kVA 980W Line-Interactive UPS;USB cable;DB9 cable;Owner's manual
|
Output Capacity (Watts)
|
980
|
Product Certifications
|
CSA (Canada); NOM (Mexico); UL 1778
|
UPS Applications
|
Large Network; High-End Desktop/Small Network
|
Runtime Full Load (min.)
|
7 min. (980W)
|