Promotion Restriction
|
Not eligible for promotion
|
Item
|
Smart UPS
|
UPS Type
|
Line Interactive
|
Mounting
|
Tower
|
Input Voltage
|
110V AC
|
Output Voltage
|
120V AC
|
Backup Time (Half/Full Load)
|
24 min/8 min
|
Transfer Time
|
2-4 milliseconds
|
Battery Type
|
Valve Regulated Lead Acid (VRLA)
|
WatchDog Compatibility
|
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Overvoltage Correction
|
Input voltages between 128 and 143V are reduced by 9%
|
AC Mode Efficiency Rating (100% Load)
|
0.91
|
Output Receptacles
|
(6) 5-15R
|
UPS AC Suppression Joule Rating
|
510
|
Undervoltage Correction
|
Input voltages between 96 and 107V are boosted by 10%
|
Relative Humidity
|
0 to 95%, non-condensing
|
Output Isolation Transformer
|
Professional grade load isolation transformer
|
Cooling Method
|
Fan
|
UPS AC Suppression Response Time
|
Instantaneous
|
Severe Undervoltage Correction
|
Input voltages between 85 and 95V are boosted by 20%
|
Battery Recharge Rate (Included Batteries)
|
Less than 4.5 hours from 10% to 90%
|
Primary Form Factor
|
Tower
|
Insertion Loss
|
65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz
|
Battery Access
|
Battery access door
|
UPS Input Connection Type
|
5-15P
|
Switches
|
2 Switches control off/on power status and alarm-cancel/self-test operation
|
Expandable Runtime
|
No
|
Nominal Input Voltage(s) Supported
|
120V AC
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
Individually Controllable Load Banks
|
No
|
Half Load Runtime (min.)
|
24 min. (350w)
|
Output Voltage Regulation (Line Mode)
|
-18%, +8%
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
Surge Voltage Attenuation
|
N-G 2000:1, L-G 240:1, L-N 100:1
|
Output Volt Amp Capacity (VA)
|
1000
|
Battery Replacement Description
|
Hot-swappable, user replaceable batteries
|
Surge Voltage Withstand Capability
|
ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
|
Communications Cable
|
USB cable included
|
UPS Certifications
|
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
|
Rated input current (Maximum Load)
|
7.6A
|
Output AC Waveform (AC Mode)
|
Sine wave
|
Communications Interface
|
USB
|
Power Factor
|
0.7
|
Low Voltage Transfer to Battery Power (Setpoint)
|
81
|
Output AC Waveform (Battery Mode)
|
PWM sine wave
|
Hot-Swap PDU options
|
PDUB15 (2U / 8 5-15R outlets)
|
PowerAlert Software
|
For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert
|
Input Phase
|
Single-Phase
|
Recommended Electrical Service
|
15A 120V
|
Internal UPS Replacement Battery Cartridge
|
RBC53
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143
|
High Voltage Transfer to Battery Power (Setpoint)
|
143
|
UPS Housing Material
|
PVC
|
Installation Form Factors Supported with Optional Accessories
|
Wallmount (UPSWM - tower mounting kit)
|
Full Load Runtime (min.)
|
8 min. (700w)
|
EMI / RFI AC Noise Suppression
|
Yes
|
Frequency Compatibility
|
60 Hz
|
Nominal Voltage Details
|
115v nominal output in battery mode
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Alarm Cancel Operation
|
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
Installation Form Factors Supported with Included Accessories
|
Tower
|
Output Watt Capacity (Watts)
|
700
|
Output kVA Capacity (kVA)
|
1
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V
|
LED Indicators
|
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
Audible Alarm
|
Audible alarm indicates power-failure and low-battery conditions
|
DC System Voltage (VDC)
|
36
|
High Availability UPS Features
|
Hot swappable batteries
|
Typical Battery Recharge Time
|
4 Hour
|
Package Contents
|
OmniSmart OMNI1000ISO 1000VA Tower UPS, OMNI1000ISO UPS System, USB cable, Owner's manual with warranty information
|
Form Factor
|
Tower
|
Certifications & Standards
|
UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class A (Emissions), NOM (Mexico)
|
Backup/Run Time (Half Load)
|
24 Minute
|
Backup/Run Time (Full Load)
|
8 Minute
|
Software Included
|
PowerAlert Software
|
Additional Information
|
Ideal for providing a continuous clean grounding reference, voltage regulation and backup power for sensitive POS, networking and home-theater applications.
|
Product Line
|
OmniSmart
|
USB
|
Yes
|
Product Name
|
OmniSmart OMNI1000ISO 1000VA Tower UPS
|
Load Capacity
|
1000 VA/700 W
|
Plug/Connector Type
|
NEMA 5-15P
|
Product Type
|
Line-interactive UPS
|
Receptacle Detail
|
6 x NEMA 5-15R
|
Operating Elevation (ft.)
|
6561 ft. (2000 m) above sea level
|
UPS Applications
|
High-End Desktop/Small Network; Retail/Point of Sale; Hospitality
|
Runtime Half Load (min.)
|
24 min. (350W)
|
Output Capacity Details
|
5.8A @ 120V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds
|
Product Certifications
|
CSA (Canada); NOM (Mexico); UL 1778
|
AC Economy Mode Efficiency Rating (100% Load)
|
0.91
|
Product Compliance
|
FCC Part 15 Class A (USA)
|
Output Capacity (VA)
|
1000
|
Output Capacity (Watts)
|
700
|
Package Includes
|
OMNI1000ISO UPS System;USB cable;Instruction manual
|
Runtime Full Load (min.)
|
8 min. (700W)
|
Frequency Compatibility Details
|
Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
|