Item
|
Smart UPS
|
VA Rating - UPS Systems
|
700.0 VA
|
UPS Type
|
Line Interactive
|
Watts - UPS Systems
|
450.0 W
|
Power Rating
|
700VA
|
Mounting
|
Tower
|
Input Voltage - UPS Systems
|
120V AC
|
Output Voltage - UPS Systems
|
120V AC
|
Wattage
|
450 W
|
Input Voltage
|
120/230V AC
|
Output Voltage
|
110/115/120V AC
|
Outlet Type - UPS Systems
|
UPS/Surge
|
Backup Time (Half/Full Load)
|
54.5 min/22.2 min
|
Outlet Type
|
UPS/Surge
|
Medical Grade
|
No
|
Number of Outlets
|
6
|
Automatic Volts Regulation
|
Yes
|
NEMA Plug Configuration
|
5-15p
|
NEMA Receptacle Configuration
|
5-15R
|
Hz
|
50/60 Hz
|
Footnotes
|
3,4,7,8,9
|
Special Features
|
Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output
|
Input Current
|
4.8 A / 2.6 A
|
Display Type
|
LED
|
Fax/Modem Line Protection
|
No
|
Phase
|
1
|
Transfer Time
|
2 to 4 msec
|
Mounting - UPS Systems
|
Tower
|
Standards
|
CE, CSA, FCC Part 15 Category A (EMI), TAA Compliant, UL 1778
|
Includes
|
Detachable Power Cord, USB Cables and DB9 Serial Cables
|
Ports
|
DB9 Serial, EPO, SNMP/Web Slot, USB(HID Enabled)
|
Watts
|
450W
|
Green Certification or Other Recognition
|
Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), CE (IEC62040 / European Union), FCC Class A (Emissions)
|
Backup/Run Time (Full Load)
|
22 Minute/55 Minute
|
Capacity - Batteries
|
700 VA/450 W
|
Input Connection
|
6 ft Cord with NEMA 5-15P Plug, C14 Inlet
|
Battery Type
|
Valve Regulated Lead Acid (VRLA)
|
Battery Replacement Description
|
Hot-swappable, user replaceable batteries
|
Individually Controllable Load Banks
|
No
|
Alarm Cancel Operation
|
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
Relative Humidity
|
0 to 95%, non-condensing
|
UPS Housing Material
|
Steel
|
Undervoltage Correction
|
A voltage boost of 14% applies when input voltage is between 83 and 104 (120V), 159V and 199V (230V)
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
|
UPS AC Suppression Response Time
|
Instantaneous
|
EMI / RFI AC Noise Suppression
|
Yes
|
Cooling Method
|
Fan
|
Network Monitoring Port Description
|
Supports detailed monitoring of UPS and site power conditions
|
Output Receptacles
|
(6) 5-15R
|
AC Mode BTU / Hr. (Full Load)
|
41
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V
|
Frequency Compatibility Details
|
Automatic frequency selection
|
AC Mode Efficiency Rating (100% Load)
|
0.98
|
LED Indicators
|
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
UPS Input Connection Description
|
Detachable 120v 5-15P input cable included
|
UPS Input Connection Type
|
5-15P; C14 inlet
|
UPS AC Suppression Joule Rating
|
570
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
|
Audible Alarm
|
Audible alarm indicates power-failure and low-battery conditions
|
Input Phase
|
Single-Phase
|
Output AC Waveform (Battery Mode)
|
Pure Sine wave
|
UPS Certifications
|
CE; Meets FCC Part 15 Category A (EMI); TAA Compliant; Tested to CSA (Canada); Tested to UL1778 (USA)
|
DC System Voltage (VDC)
|
24
|
Low Voltage Transfer to Battery Power (Setpoint)
|
83 (120v), 159 (230v)
|
Output Watt Capacity (Watts)
|
450
|
Expandable Runtime
|
No
|
Output Voltage Regulation (Line Mode)
|
-21%, +8%
|
Rated input current (Maximum Load)
|
4.8A (120V), 2.6A (230V)
|
High Voltage Transfer to Battery Power (Setpoint)
|
147 (120v), 282 (230v)
|
Output AC Waveform (AC Mode)
|
Sine wave
|
Communications Interface
|
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
|
Primary Form Factor
|
Tower
|
Internal UPS Replacement Battery Cartridge
|
RBC54
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 (120V), 159 to 282 (230V)
|
Switches
|
2 Switches control off/on power status and alarm-cancel/self-test operation
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
|
Network Management Cards
|
SNMPWEBCARD; TLNETCARD; WEBCARDLX
|
Half Load Runtime (min.)
|
54.5 min. (225w)
|
Output Volt Amp Capacity (VA)
|
700
|
Full Load Runtime (min.)
|
22.2 min. (450w)
|
Overvoltage Correction
|
A voltage reduction of 12% applies when input voltage is between 125 and 147 (120V), 240 to 282 (230V)
|
Nominal Input Voltage(s) Supported
|
120V AC; 230V AC
|
Input Circuit Breakers
|
6A
|
Frequency Compatibility
|
50 / 60 Hz
|
Battery Recharge Rate (Included Batteries)
|
Less than 4 hours from 10% to 90% (typical, full load discharge)
|
High Availability UPS Features
|
Hot swappable batteries
|
Nominal Voltage Details
|
120v nominal output in battery mode
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
Battery Access
|
Battery access door
|
Product Type
|
Line-interactive UPS
|
Load Capacity
|
700 VA/450 W
|
Product Line
|
SmartPro
|
Form Factor
|
Tower
|
USB
|
Yes
|
Product Name
|
SMART700DV 700VA Dual Voltage Tower Line Interactive UPS TAA Compliant
|
Certifications & Standards
|
Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), CE (IEC62040 / European Union), FCC Class A (Emissions)
|
Serial Port
|
Yes
|
Network Management
|
SNMP Manageable
|
Package Contents
|
SmartPro SMART700DV 700VA Tower UPS, SMART700DV UPS System, Detachable NEMA5-15P power cord, USB cabling and DB9 serial cabling, Manual with warranty information
|
Backup/Run Time (Half Load)
|
55 Minute
|
Receptacle Detail
|
6 x NEMA 5-15R
|
Emergency Power OFF
|
Yes
|
Typical Battery Recharge Time
|
4 Hour
|
Additional Information
|
Ideal for military, relief or other applications where low-voltage 120V output is required, Switches:Includes 2 front panel switches one main on/off power switch and one dual function "alarm cancel" / "self test" button, Low voltage transfer to battery power: Switches to battery power as line voltage drops to 83v or lower (159v at 230v nominal), resets to line power as line voltage increases to 87v or higher (167V at 230V nominal), High voltage transfer to battery power: Switches to battery power as line voltage increases to 147V or higher (282V at 230V nominal), resets to line power when line voltage drops to 143v or lower (274V at 230V nominal)
|
Plug/Connector Type
|
IEC 320-C14
|
TAA Compliant
|
Yes
|
Package Includes
|
SMART700DV UPS System;Detachable NEMA 5-15P power cord;USB cabling and DB9 serial cabling;Manual with warranty information
|
Runtime Full Load (min.)
|
22.2 min. (450W)
|
Installation Form Factors Supported with Included Accessories
|
Tower
|
Product Compliance
|
CE (Europe); FCC Part 15 Class A (USA); Trade Agreements Act (TAA)
|
Output Capacity (VA)
|
700
|
UPS Applications
|
Large Network
|
Product Certifications
|
CSA (Canada); UL 1778
|
Output Capacity (Watts)
|
450
|
Runtime Half Load (min.)
|
54.5 min. (225W)
|