Item
|
Smart UPS
|
UPS Type
|
Line Interactive
|
VA Rating - UPS Systems
|
5.0 kVA
|
Watts - UPS Systems
|
4.0 kW
|
Power Rating
|
5 kVA
|
Input Voltage - UPS Systems
|
208V AC
|
Mounting
|
Rack/Tower
|
Output Voltage - UPS Systems
|
120V AC, 208V AC
|
Wattage
|
4 kW
|
Input Voltage
|
208V AC
|
Output Voltage
|
120/208V AC
|
Backup Time (Half/Full Load)
|
38 min/16 min
|
Outlet Type - UPS Systems
|
(6) Surge, (6) UPS/Surge
|
Outlet Type
|
UPS/Surge
|
Medical Grade
|
No
|
Number of Outlets
|
14
|
Display Type
|
LED
|
Automatic Volts Regulation
|
Yes
|
Phase
|
1
|
Transfer Time
|
2 to 4 msec
|
Includes
|
BP48V60RT3U Battery Pack, Mounting Hardware, PowerAlert Software and Cables
|
NEMA Plug Configuration
|
L6-30P
|
Standards
|
CSA, FCC Part 15 Category A (EMI), NOM, UL 1778
|
Ports
|
Contact Closure, DB9 Serial, USB
|
Hz
|
60 Hz
|
Watts
|
4kW
|
Mounting - UPS Systems
|
Rack/Tower
|
Input Current
|
24 A
|
Special Features
|
Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output
|
Fax/Modem Line Protection
|
No
|
Footnotes
|
3,4,9
|
NEMA Receptacle Configuration
|
5-15R, 5-20R, L14-30R, L6-30R
|
Green Certification or Other Recognition
|
UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications
|
Voltage
|
208
|
Capacity - Batteries
|
5000 VA/4000 W
|
Operating Temp. Range
|
104°F (40°C)
|
Battery Type
|
Sealed Lead Acid (SLA)
|
Backup/Run Time (Full Load)
|
16 Minute/38 Minute
|
Input Connection
|
10 ft Cord with NEMA L6-30P Plug
|
Output Receptacles
|
(10) 5-15R; (2) 5-15/20R; (1) L14-30R; (1) L6-30R
|
Network Management Cards
|
SNMPWEBCARD ; WEBCARDLX
|
Communications Interface
|
USB; DB9 Serial; Contact closure
|
AC Mode Efficiency Rating (100% Load)
|
0.94
|
Output Watt Capacity (Watts)
|
4000
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
|
Alarm Cancel Operation
|
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
Frequency Compatibility
|
60 Hz
|
Rated input current (Maximum Load)
|
24A max. in factory L6-30P configuration; 27A max. when powered by 50A plug or hardwire input
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
LED Indicators
|
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
Recommended Electrical Service
|
30A 208V
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V; 208V
|
Audible Noise
|
45 dBA maximum, front side 1m
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
Audible Alarm
|
Audible alarm indicates power-failure, overload and low-battery conditions
|
Output Circuit Breakers
|
15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and L14-30R outlets are unbreakered
|
High Availability UPS Features
|
Hot swappable batteries
|
Power Factor
|
0.8
|
Installation Form Factors Supported with Optional Accessories
|
2 post rackmount ( 2POSTRMKITHD ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND )
|
Relative Humidity
|
0 to 95%, non-condensing
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282
|
External Battery Pack Compatibility
|
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
|
Severe Undervoltage Correction
|
Input voltages between 151V and 179 are boosted by 24%
|
Nominal Voltage Details
|
208/120V nominal output in battery mode
|
WatchDog Compatibility
|
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Switches
|
2 Switches control off/on power status and alarm-cancel/self-test operation
|
Cooling Method
|
Fans
|
Load Management Receptacles
|
Eight switchable single-outlet 5-15R load banks
|
Battery Replacement Description
|
Hot-swappable, user replaceable batteries
|
Output Capacity Details
|
Maximum output increases to 4800W when hardwire or user-supplied 50A rated input plug is used
|
Installation Form Factors Supported with Included Accessories
|
4 post 19 inch rackmount
|
UPS AC Suppression Joule Rating
|
1020
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
UPS Certifications
|
Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
|
Low Voltage Transfer to Battery Power (Setpoint)
|
151
|
Input Circuit Breakers
|
30A double-pole
|
Undervoltage Correction
|
Input voltages between 180V and 199 are boosted by 12%
|
Primary Form Factor
|
Rackmount
|
Nominal Input Voltage(s) Supported
|
208V AC
|
Full Load Runtime (min.)
|
16 min. (4000w)
|
UPS AC Suppression Response Time
|
Instantaneous
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Output AC Waveform (AC Mode)
|
Sine wave
|
Half Load Runtime (min.)
|
38 min. (2000w)
|
EMI / RFI AC Noise Suppression
|
Yes
|
Included Mounting Accessory Description
|
Set of two included 4POSTRAILKIT mounting brackets enables installation of UPS and Battery Pack in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
Output kVA Capacity (kVA)
|
5
|
Individually Controllable Load Banks
|
Yes
|
Expandable Runtime
|
Yes
|
Input Phase
|
Single-Phase
|
Communications Cable
|
USB and DB9 cabling included
|
Network Monitoring Port Description
|
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
|
Overvoltage Correction
|
Input voltages between 240V and 260 are reduced by 12%
|
Expandable Battery Runtime
|
Extended runtime supported via optional external battery packs
|
Battery Mode BTU / Hr. (Full Load)
|
1518
|
Output Voltage Regulation (Line Mode)
|
208 & 120V (-10%, +20%)
|
Output kW Capacity (kW)
|
4
|
UPS Input Connection Type
|
L6-30P
|
DC System Voltage (VDC)
|
48
|
Output Volt Amp Capacity (VA)
|
5000
|
Output AC Waveform (Battery Mode)
|
Pure Sine wave
|
UPS Housing Material
|
Steel
|
High Voltage Transfer to Battery Power (Setpoint)
|
260
|
Grounding Lug
|
Back panel grounding lug
|
Battery Recharge Rate (Included Batteries)
|
Less than 4 hours from 10% to 90% (typical, full load discharge)
|
Additional Information
|
Large 5000VA / 4000 watt output capacity with full time sine wave output offers guaranteed compatibility with all equipment types, High power density 5kVA power module and battery pack occupy only 3 rack spaces (3U) each (UPS and battery pack use 6U when installed), 38 minutes half load runtime, expandable runtime with multiple external battery packs (part# BP48V60RT3U), Line interactive voltage regulation corrects severe brownouts and overvoltages without using battery power, Dual voltage output is simultaneously compatible with both 208 and 120V equipment, 14 total outlets (120V: 10 5-15R, 2 5-20R / 208v: 1 L6-30R, 1 L14-30R), Diagnostic LEDs provide visual indication of 17 separate performance conditions, Included PowerAlert Software provides e-mail or pager notification of power problems and the simultaneous automatic unattended shutdown of multiple servers, 4 built-in communications ports (2-DB9, 2-USB) for remote monitoring and unattended shutdown, Slot for SNMP/web card SNMPWEBCARD and environmental sensor ENVIROSENSE for remote communications in large IP environments, 8 customized load management receptacles can be individually powered off and back on again via software interface to reboot remote equipment or automatic "load shedding" of less critical loads to extend battery runtime for the most critical equipment, Emergency Power Off (EPO) interface for emergency shutoff in large facilities, Hot-swappable / user replaceable batteries allow on-site battery replacement through the front panel without powering off connected equipment or removing the UPS from the rack, UPS battery set ships fully assembled and ready for connection to the power module, no time consuming, connection of individual internal batteries by user is necessary, $250,000 Ultimate Lifetime Insurance (USA & Canada Only). No warranty cards required for coverage!, 2 year manufacturers product warranty
|
Battery Chemistry
|
Lead Acid
|
Maximum Operating Temperature
|
104°F (40°C)
|
Battery Life
|
6 Year
|
Receptacle Detail
|
1 x NEMA L14-30R, 2 x NEMA 5-20R, 10 x NEMA 5-15R, 1 x NEMA L6-30R
|
Alarm
|
Low Battery, On Battery, Overload
|
Typical Battery Recharge Time
|
4 Hour
|
Product Name
|
SMART5000RT3U 5000 VA Rack/Tower Line Interactive UPS
|
Load Capacity
|
5000 VA/4000 W
|
Total Number of Expansion Slots
|
1
|
Product Line
|
SmartPro
|
Backup/Run Time (Half Load)
|
38 Minute
|
Hot Swappable
|
Yes
|
Product Type
|
Line-interactive UPS
|
Certifications & Standards
|
UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications
|
USB
|
Yes
|
Waveform Type
|
Sine Wave
|
Network Management
|
SNMP Manageable
|
Status Indicators
|
5 front panel LEDs - Green 5 front panel LEDs - Green POWER LED, Green VOLTAGE CORRECTION LED, 3 color BATTERY CHARGE LED, 3 color OUTPUT LOAD LED, red BATTERY WARNING LED
|
Package Contents
|
SMART5000RT3U UPS, SMART5000RT3U UPS System, BP48V60RT3U battery pack, PowerAlert Software and cabling, Mounting hardware, Instruction manual with warranty information
|
Emergency Power OFF
|
Yes
|
Plug/Connector Type
|
NEMA L6-30P
|
Package Includes
|
SMART5000RT3U UPS System;BP48V60RT3U battery pack;USB & DB9 Serial cabling;Mounting hardware;Instruction manual
|
Output Capacity (VA)
|
5000
|
Product Compliance
|
FCC Part 15 Class A (USA)
|
UPS Applications
|
Large Network
|
Runtime Half Load (min.)
|
38 min.
|
Grounding Details
|
Back panel grounding lug
|
Runtime Full Load (min.)
|
16 min.
|
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
|
1518
|
Product Certifications
|
CSA (Canada); NOM (Mexico); UL 1778
|
Output Capacity (Watts)
|
4000
|