Full Load Amps-Inductive
|
80 A
|
Item
|
IEC Magnetic Contactor
|
Full Load Amps-Resistive
|
125 A
|
Number of Poles
|
4
|
Coil Volts
|
120 V AC
|
Aux. Contact Configuration
|
4NO
|
Standards
|
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, BV, RINA, GOST, LROS, DNV, GL, CCC, UL, CSA, THIEC 60068-2-30
|
Series
|
LC1D
|
Features
|
Without Built-In Suppressor Module
|
Application
|
Resistive Load
|
Fire Rating
|
UL 94 V1
|
Tightening Torque
|
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
|
Impedance
|
0.8 mOhm
|
Vibration Resistance
|
3 G (Contactor Closed), 2 G (Contactor Open)
|
Max. Temperature
|
850°C
|
Thermal Amperage
|
125 A (at 60°C Power Circuit)
|
Mechanical Durability
|
10 Mcycles
|
Includes Protective Cover
|
No
|
Impulse Withstand Voltage
|
8 kV
|
Rated Making Capacity
|
1100 A @ 440V (Power Circuit)
|
Hold VA
|
22 VA
|
Control Circuit Voltage Limits
|
Operational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 60 Hz); Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz)
|
Overvoltage Category
|
CAT III
|
Max. Operating Watts
|
22 kW (at 220 to 230V AC 50/60 Hz), 37 kW (at 380 to 400V AC 50/60 Hz), 45 kW (at 660 to 690V AC 50/60 Hz), 55 kW (at 500V AC 50/60 Hz), 45 kW (at 415 to 440V AC 50/60 Hz)
|
Electrical Connection
|
Screw Clamp Terminals
|
Fuse Amps
|
200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit)
|
Rated Breaking Capacity
|
1100 A @ 440V
|
Mounts On
|
Plate, Rail
|
Inrush VA
|
220 VA
|
Rated Short-Time Withstand Current
|
640 A (at 40°C for 10 s Power Circuit), 990 A (at 40°C for 1 s Power Circuit), 135 A (at 40°C for 10 min Power Circuit), 320 A (at 40°C for 1 min Power Circuit)
|
Rated Insulation Volts
|
600/1000V
|
IP Rating
|
IP20
|
Electrical Durability
|
0.8 Mcycles (125 A, AC-1, Less than 440 V)
|
Shock Resistance
|
10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open)
|
Watts Loss
|
6 to 10W
|
Operating Time
|
20 to 35 ms (Closing), 6 to 20 ms (Opening)
|
Operating Speed
|
3600 cycles per hr
|
Rated Voltage
|
690V AC, 300V DC
|
Environmental Attributes
|
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
|
Net Weight
|
1.76 kg
|
Maximum Operating Rate
|
3600 cyc/h 60°C
|
Mechanical Robustness
|
vibrations contactor open 2 Gn, 5...300 Hz) , shocks contactor open 8 Gn for 11 ms) , vibrations contactor closed 3 Gn, 5...300 Hz) , shocks contactor closed 10 Gn for 11 ms)
|
Inrush Power In Va
|
220-220 VA 60 Hz cos phi 0.75 (at 20°C)
|
[Ue] Rated Operational Voltage
|
power circuit <= 300 V DC 25...400 Hz, power circuit <= 690 V AC
|
Motor Power Kw
|
22 kW at 220...230 V AC 50/60 Hz, 37 kW at 380...400 V AC 50/60 Hz, 45 kW at 660...690 V AC 50/60 Hz, 55 kW at 500 V AC 50/60 Hz, 45 kW at 415...440 V AC 50/60 Hz
|
Pvc Free
|
Yes
|
Power Dissipation Per Pole
|
12.5 W AC-1
|
Pole Contact Composition
|
4 NO
|
Poles Description
|
4P
|
Protective Treatment
|
THIEC 60068-2-30
|
Protective Cover
|
without
|
Control Circuit Type
|
AC 60 Hz
|
[Ith] Conventional Free Air Thermal Current
|
125 A (at 60°C) for power circuit
|
Product or Component Type
|
contactor
|
Mounting Support
|
plate, rail
|
[Uimp] Rated Impulse Withstand Voltage
|
8 kV IEC 60947
|
Range
|
TeSys
|
Flame Retardance
|
V1 conforming to UL 94
|
Heat Dissipation
|
6-10 W at 60 Hz
|
Pollution Degree
|
3
|
Irms Rated Making Capacity
|
1100 A at 440 V for power circuit conforming to IEC 60947
|
Average Impedance
|
0.8 mOhm - Ith 125 A 50 Hz for power circuit
|
Operating Altitude
|
0...9842.52 ft (0...3000 m)
|
Permissible Ambient Air Temperature Around The Device
|
-40-60°C, 60-70°C with derating
|
Climatic Withstand
|
IACS E10 exposure to damp heat
|
Fire Resistance
|
850°C IEC 60695-2-1
|
Ip Degree of Protection
|
IP20 front face IEC 60529
|
[Uc] Control Circuit Voltage
|
120 V AC 60 Hz
|
[Ie] Rated Operational Current
|
125 A (at <60°C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60°C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60°C) at <= 440 V AC AC-3e for power circuit, 55 A (at <60°C) at <= 400 V AC AC-4 for power circuit
|
Hold-In Power Consumption In Va
|
22-22 VA 60 Hz cos phi 0.3 (at 20°C)
|
Associated Fuse Rating
|
200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
|
Connections - Terminals
|
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end
|
[Ui] Rated Insulation Voltage
|
power circuit 600 V CSA, power circuit 600 V UL, power circuit 1000 V IEC 60947-4-1
|
[Icw] Rated Short-Time Withstand Current
|
640 A 40°C - 10 s for power circuit, 990 A 40°C - 1 s for power circuit, 135 A 40°C - 10 min for power circuit, 320 A 40°C - 1 min for power circuit
|
Utilisation Category
|
AC-1, AC-3, AC-3e, AC-4
|
Range of Product
|
TeSys Deca
|