Full Load Amps-Inductive
|
50 A
|
Item
|
IEC Magnetic Contactor
|
Action
|
Reversing
|
Number of Poles
|
3
|
Coil Volts
|
120 V AC
|
Aux. Contact Configuration
|
1NO/1NC
|
Auxiliary Contact Form
|
1NO/1NC
|
Standards
|
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
|
Series
|
TeSys Deca
|
IP Rating
|
IP20
|
Includes Auxiliary Contacts
|
Yes
|
Maximum Operating Temperature
|
140 Degrees F
|
NEMA Enclosure Rating
|
No Enclosure
|
Embedded Surge Suppressor
|
No
|
Number of Normally Open Main Contacts
|
1
|
Mechanical Operating Durability
|
6,000,000
|
Number of Normally Closed Main Contacts
|
0
|
Terminal Connection Type
|
Screw Clamp Terminals
|
Frequency
|
60 Hz
|
Contactor Style
|
IEC
|
Coil Voltage
|
120V AC
|
Full Load Current - Resistive
|
80 A
|
Reversing Capability
|
Reversing
|
Minimum Operating Temperature
|
23 Degrees F
|
Maximum Voltage Rating
|
120V AC
|
Full Load Current - Inductive
|
50 A
|
Number of Auxillary Contacts
|
3
|
Motor Power KW
|
15 kW 220 to 240 V AC 50/60 Hz; 22 kW 380 to 400 V AC 50/60 Hz; 25 kW 415 V AC 50/60 Hz; 30 kW 440 V AC 50/60 Hz; 30 kW 500 V AC 50/60 Hz; 33 kW 660 to 690 V AC 50/60 Hz
|
IP Degree Of Protection
|
IP2X IEC 60529; IP2X VDE 0106
|
Rated Voltage
|
1000V AC
|
Rated Insulation Voltage
|
Control circuit 600 V CSA; Control circuit 600 V UL; Power circuit 600 V CSA; Power circuit 600 V UL; Control circuit 690 V IEC 60947-1; Power circuit 690 V IEC 60947-1
|
Fuse Amps
|
10 A (Control Circuit), 100 A (Type 1 and 2 Power Circuit)
|
Fire Resistance
|
1562°F (850°C) IEC 60695-2-1
|
Switching Current
|
5 mA (Control Circuit)
|
Maximum Operating Rate
|
3600 cyc/h 140°F (60°C)
|
Product Certifications
|
GL; UL; RINA; GOST; CSA; LROS (Lloyds register of shipping); CCC; DNV; BV; UKCA
|
Shock Resistance
|
10 G (Contactor Closed), 8 G (Contactor Open)
|
Application
|
Motor Control
|
Mechanical Durability
|
6 Mcycles
|
Operating Altitude
|
9842.52 ft (3000 m) without derating
|
Insulation Resistance Range
|
Greater Than 10 Mohms (Control Circuit)
|
Environmental Attributes
|
Mercury Free, PVC Free, Toxic Heavy Metal Free
|
Poles Description
|
3P
|
Rated Operational Current
|
Power circuit 50 A AC AC-3 140°F (60°C))
|
Overvoltage Category
|
CAT III
|
Rated Making Capacity
|
140 A (AC Control Circuit), 900 A @ 440V (Power Circuit)
|
Minimum Switching Voltage
|
17 V for control circuit
|
Conventional Free Air Thermal Current
|
10 A (at 140°F (60°C)) for control circuit; 80 A (at 140°F (60°C)) for power circuit
|
Features
|
Without Built-In Bi-Directional Peak Limiting Diode Suppressor
|
Impulse Withstand Voltage
|
6 kV
|
Auxiliary Contact Composition
|
1 NO + 1 NC
|
Inrush VA
|
200 to 220 VA
|
Switching Voltage
|
17 V (Control Circuit)
|
Control Circuit Voltage Limits
|
Drop-Out: 0.3 to 0.6 Uc (at 60°C 50/60 Hz); Operational: 0.8 to 1.1 Uc (at 60°C 50 Hz), 0.85 to 1.1 Uc (at 60°C 60 Hz)
|
Flame Retardance
|
V1 conforming to UL 94
|
Heat Dissipation
|
6 to 10 W at 50/60 Hz for control circuit
|
Control Circuit Voltage
|
120 V AC 60 Hz
|
Protective Treatment
|
TH 3)IEC 60068
|
Interlocking Type
|
Mechanical
|
Safety Reliability Level
|
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
|
Utilisation Category
|
AC-2; AC-3; AC-4
|
Rated Breaking Capacity
|
900 A @ 440V
|
Includes Protective Cover
|
Yes
|
Average Impedance
|
80 A 50 Hz for power circuit
|
Power Dissipation Per Pole
|
3.7 W AC-3 - Ith 80 A
|
Control Circuit Type
|
AC
|
Fire Rating
|
UL 94 V1
|
Operating Time
|
12 to 26 ms (Closing), 4 to 19 ms (Opening)
|
Rated Operational Voltage
|
Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz
|
Coil Type
|
Standard
|
Inrush Power in VA
|
200 VA cos phi 0.75 (at 68°F (20°C)); 220 VA cos phi 0.75 (at 68°F (20°C))
|
Max. Temperature
|
850°C
|
Ambient Air Temperature For Operation
|
23 to 140°F (-5 to 60°C)
|
Protective Cover
|
With
|
Non-Overlap Time
|
1.5 ms
|
Tightening Torque
|
1.7 Nm (Control Circuit), 5 to 8 Nm (Power Circuit)
|
Hold-In Power Consumption in VA
|
20 VA 50 Hz cos phi 0.3 (at 68°F (20°C)); 22 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 26 VA 50 Hz cos phi 0.3 (at 68°F (20°C)); 26 VA 60 Hz cos phi 0.3 (at 68°F (20°C))
|
Connections - Terminals
|
Control circuit 1 0.00 to 0.01 in² (1 to 4 mm²)flexible with cable end; Control circuit 1 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; Control circuit 1 0.00 to 0.01 in² (1 to 4 mm²)solid without cable end; Control circuit 2 0.00 to 0.00 in² (1 to 2.5 mm²)flexible with cable end; Control circuit 2 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; Control circuit 2 0.00 to 0.01 in² (1 to 4 mm²)solid without cable end; Power circuit 1 0.00 to 0.05 in² (1 to 35 mm²)flexible with cable end; Power circuit 1 0.00 to 0.05 in² (1 to 35 mm²)flexible without cable end; Power circuit 1 0.00 to 0.05 in² (1 to 35 mm²)solid without cable end; Power circuit 2 0.00 to 0.04 in² (1 to 25 mm²)flexible with cable end; Power circuit 2 0.00 to 0.04 in² (1 to 25 mm²)flexible without cable end; Power circuit 2 0.00 to 0.04 in² (1 to 25 mm²)solid without cable end; Power circuit 2 0.00 to 0.05 in² (1 to 35 mm²)flexible with cable end; Power circuit 2 0.00 to 0.05 in² (1 to 35 mm²)flexible without cable end; Power circuit 2 0.00 to 0.05 in² (1 to 35 mm²)solid without cable end
|
Rated Impulse Withstand Voltage
|
6 kV IEC 60947
|
Watts Loss
|
6 to 10W
|
Hold VA
|
20 to 26 VA (at 50 Hz 20°C), 22 to 26 VA (at 60 Hz 20°C)
|
Mounts On
|
Plate, Rail
|
Insulation Resistance
|
Greater than 10 MOhm for control circuit
|
Pole Contact Composition
|
3 NO
|
Minimum Switching Current
|
5 mA for control circuit
|
Vibration Resistance
|
3 G (Contactor Closed), 2 G (Contactor Open)
|
Thermal Amperage
|
10 A (at 60°C Control Circuit), 80 A (at 60°C Power Circuit)
|
Ambient Air Temperature For Storage
|
-76 to 176°F (-60 to 80°C)
|
Net Weight
|
2.4 kg
|
Max. Operating Watts
|
15 kW (at 220 to 240V AC 50/60 Hz), 22 kW (at 380 to 400V AC 50/60 Hz), 25 kW (at 415V AC 50/60 Hz), 30 kW (at 440V AC 50/60 Hz), 30 kW (at 500V AC 50/60 Hz), 33 kW (at 660 to 690V AC 50/60 Hz)
|
Associated Fuse Rating
|
10 A gG for control circuit conforming to IEC 60947-5-1; 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
|
Rated Insulation Volts
|
600/690V
|
Coil Technology
|
Without built-in bidirectional peak limiting diode suppressor
|
Mounting Support
|
Plate; Rail
|
Permissible Ambient Air Temperature Around The Device
|
-40 to 158°F (-40 to 70°C) at Uc
|
Assembly Style
|
Ready assembled
|
Product Or Component Type
|
Reversing contactor
|
Operating Speed
|
3600 cycles per hr
|
Auxiliary Contacts Type
|
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
|
IRMS Rated Making Capacity
|
140 A AC for control circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947
|