Item
|
UPS System
|
UPS Type
|
Standby
|
VA Rating - UPS Systems
|
550.0 VA
|
Watts - UPS Systems
|
300.0 W
|
Power Rating
|
550VA
|
Input Voltage - UPS Systems
|
120V AC
|
Mounting
|
Desktop/Tower
|
Voltage
|
120
|
Output Voltage - UPS Systems
|
115V AC, 120V AC
|
Wattage
|
300 W
|
Input Voltage
|
120VAC
|
Output Voltage
|
115V AC
|
Outlet Type - UPS Systems
|
(4) Surge, (4) UPS/Surge
|
Backup Time (Half/Full Load)
|
10 min/3.5 min
|
Outlet Type
|
(4) Surge, (4) UPS/Surge
|
Medical Grade
|
No
|
Number of Outlets
|
8
|
NEMA Receptacle Configuration
|
5-15R
|
NEMA Plug Configuration
|
5-15p
|
Transfer Time
|
3 msec from Battery to AC, 4 msec from AC to Battery
|
Standards
|
CSA, ENERGY STAR Qualified, FCC Part 15 Category B (EMI), NOM, ROHS (Restriction of Hazardous Substances), TAA Compliant, UL 1778
|
Phase
|
1
|
Watts
|
300W
|
Ports
|
USB (HID enabled)
|
Automatic Volts Regulation
|
No
|
Special Features
|
(3) Built-In ECO Outlets w/Auto Off, Poweralert Software
|
Hz
|
60 Hz
|
Input Current
|
10 A
|
Includes
|
USB cable
|
Mounting - UPS Systems
|
Desktop/Tower
|
Footnotes
|
4,6,9
|
Fax/Modem Line Protection
|
Yes
|
Display Type
|
LED
|
Green Environmental Attribute
|
Product Contributes To Reducing Energy Consumption
|
Green Certification or Other Recognition
|
UL 1778CSAFCC Part 15 Category B (EMI)TAA, RoHS, ENERGY STAR
|
Capacity - Batteries
|
550 VA/300 W
|
Backup/Run Time (Full Load)
|
3.50 Minute/10 Minute
|
Input Connection
|
6 ft Cord with NEMA 5-15P Plug
|
Battery Type
|
Valve Regulated Lead Acid (VRLA)
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert
|
Nominal Input Voltage(s) Supported
|
120V AC
|
Low Voltage Transfer to Battery Power (Setpoint)
|
99
|
Output AC Waveform (AC Mode)
|
Sine wave
|
Relative Humidity
|
0 to 95%, non-condensing
|
Output Receptacles
|
(8) 5-15R
|
UPS Output Receptacles (Surge Suppression Only)
|
4 UPS outlets, 4 surge-only outlets
|
Output Watt Capacity (Watts)
|
300
|
Expandable Runtime
|
No
|
Communications Cable
|
RJ to USB interface cable included
|
Frequency Compatibility
|
60 Hz
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
Network UPS Tools Compatibility
|
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
|
UPS Certifications
|
Meets FCC Part 15 Category B (EMI); TAA Compliant; Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
|
Audible Alarm
|
Audible alarm indicates power-failure and overload status
|
High Voltage Transfer to Battery Power (Setpoint)
|
139
|
LED Indicators
|
3 LEDs indicate power status, overload/check battery and ECO-mode status
|
Rated input current (Maximum Load)
|
10A
|
Recommended Electrical Service
|
15A 120V
|
UPS Input Connection Type
|
5-15P; Right-Angled
|
UPS Housing Material
|
ABS
|
Input Phase
|
Single-Phase
|
Individually Controllable Load Banks
|
No
|
Battery Recharge Rate (Included Batteries)
|
Less than 15 hours from 10% to 90%
|
Nominal Voltage Details
|
115v nominal output in battery mode
|
Communications Interface
|
USB (HID enabled)
|
DC System Voltage (VDC)
|
12
|
EMI / RFI AC Noise Suppression
|
Yes
|
AC Mode Efficiency Rating (100% Load)
|
0.99
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V
|
UPS AC Suppression Joule Rating
|
420
|
Output AC Waveform (Battery Mode)
|
PWM sine wave
|
UPS AC Suppression Response Time
|
Instantaneous
|
Output Volt Amp Capacity (VA)
|
550
|
WatchDog Compatibility
|
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Switches
|
Combination switch controls on/off power status and self-test operation; second recessed push-button switch enables ECO outlet switching
|
Half Load Runtime (min.)
|
10 min. (150w)
|
AC Mode BTU / Hr. (Full Load)
|
14
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
Installation Form Factors Supported with Included Accessories
|
Tower; Ultra-compact desktop; Wallmount
|
UPS Dataline Suppression
|
1 line TEL/DSL (1 in / 1 out)
|
Primary Form Factor
|
Desktop
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Plug/Connector Type
|
NEMA 5-15P
|
Protection Type
|
Power Failure, Brownout
|
Form Factor
|
Desktop, Wall Mountable
|
Typical Battery Recharge Time
|
15 Hour
|
TAA Compliant
|
Yes
|
Product Type
|
Standby UPS
|
Product Series
|
ECO
|
Dataline Protection
|
RJ-11
|
USB
|
Yes
|
Certifications & Standards
|
UL 1778, CSA, FCC Part 15 Category B (EMI), TAA
|
Receptacle Detail
|
8 x NEMA 5-15R
|
Backup/Run Time (Half Load)
|
10 Minute
|
Package Contents
|
ECO550UPSTAA 550 VA Desktop UPS, USB Cable, Instructional Manual with Warranty Information
|
Load Capacity
|
550 VA/300 W
|
Product Name
|
ECO550UPSTAA 550 VA Desktop ECO UPS TAA Compliant
|
Output Capacity (VA)
|
550
|
High Availability UPS Features
|
Surge/noise protection
|
Package Includes
|
ECO550UPSTAA TAA Compliant UPS System;USB cable;Instruction manual with warranty information
|
Product Certifications
|
CSA (Canada); NOM (Mexico); UL 1778
|
Runtime Full Load (min.)
|
3.5 min. (300W)
|
Product Compliance
|
FCC Part 15 Class B (USA); Trade Agreements Act (TAA)
|
Output Capacity (Watts)
|
300
|
UPS Applications
|
Computer/Peripherals
|
Runtime Half Load (min.)
|
10 min. (150W)
|