Item
|
UPS System
|
UPS Type
|
Line Interactive
|
Power Rating
|
750 VA
|
Mounting
|
Desktop/Tower
|
Wattage
|
450 W
|
Input Voltage
|
120V AC
|
Output Voltage
|
115/120V AC
|
Backup Time (Half/Full Load)
|
10 min/3 min
|
Outlet Type
|
UPS/Surge
|
Medical Grade
|
No
|
Number of Outlets
|
12
|
Automatic Volts Regulation
|
No
|
Standards
|
CSA, FCC Part 15 Category B (EMI), NOM, UL 1778
|
Display Type
|
LED
|
Footnotes
|
4
|
Hz
|
60 Hz
|
NEMA Receptacle Configuration
|
5-15R
|
Special Features
|
USB Port And Poweralert Software Enables Unattended Shutdown In Case Of Extended Power Failure
|
Ports
|
USB (HID enabled)
|
Phase
|
1
|
Includes
|
USB cable
|
NEMA Plug Configuration
|
5-15p
|
Green Environmental Attribute
|
Product Contributes To Reducing Energy Consumption
|
Input Current
|
12 A
|
Fax/Modem Line Protection
|
No
|
Transfer Time
|
2 to 4 msec
|
Input Connection
|
6 ft Cord with NEMA 5-15P Plug
|
Battery Type
|
Valve Regulated Lead Acid (VRLA)
|
WatchDog Compatibility
|
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Operating Elevation (m)
|
Up to 3000m
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
|
High Availability UPS Features
|
Battery Independent Restart
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V
|
Rated input current (Maximum Load)
|
10A
|
Output Watt Capacity (Watts)
|
450
|
Battery Recharge Rate (Included Batteries)
|
8 hours (10% to 90%)
|
UPS Housing Material
|
ABS
|
Overvoltage Correction
|
Input voltages between 128 and 145 are reduced by 15%
|
Primary Form Factor
|
Desktop
|
Output Receptacles
|
(12) 5-15R
|
UPS AC Suppression Response Time
|
Instantaneous
|
Output AC Waveform (AC Mode)
|
Pure sine wave
|
Output Voltage Regulation (Battery Mode)
|
120V (±10%)
|
Battery Replacement Description
|
Replaceable internal batteries (see manual)
|
Storage Temperature Range
|
+5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius
|
Input Phase
|
Single-Phase
|
Output Voltage Regulation (Line Mode)
|
120V (+6%/-12%)
|
UPS Dataline Suppression
|
1 line TEL/DSL or Ethernet
|
Input Circuit Breakers
|
10A
|
LED Indicators
|
2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions
|
Battery Access
|
Battery access door
|
AC Mode Efficiency Rating (100% Load)
|
>96%
|
Recommended Electrical Service
|
15A 120V
|
Nominal Input Voltage(s) Supported
|
120V AC
|
Output AC Waveform (Battery Mode)
|
PWM sine wave
|
Relative Humidity
|
0 to 90%, non-condensing
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
Individually Controllable Load Banks
|
No
|
Internal UPS Replacement Battery Cartridge
|
RBC51
|
UPS Output Receptacles (Surge Suppression Only)
|
6 UPS outlets, 6 surge-only outlets
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145
|
AC Mode BTU / Hr. (Full Load)
|
41
|
Output Volt Amp Capacity (VA)
|
750
|
Audible Alarm
|
UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
|
UPS AC Suppression Joule Rating
|
316
|
UPS Input Connection Type
|
5-15P
|
Switches
|
Power off/on switch
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Frequency Compatibility
|
50 / 60 Hz
|
High Voltage Transfer to Battery Power (Setpoint)
|
145
|
UPS Certifications
|
Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
|
Installation Form Factors Supported with Included Accessories
|
Tower; Ultra-compact desktop; Wallmount
|
Operating Elevation (ft.)
|
Up to 10,000 ft.
|
Low Voltage Transfer to Battery Power (Setpoint)
|
89
|
DC System Voltage (VDC)
|
12
|
EMI / RFI AC Noise Suppression
|
Yes
|
Communications Cable
|
USB interface cable included
|
Undervoltage Correction
|
Input voltages between 89 and 108 are boosted by 18%
|
UPS Certification Details
|
UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS A; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia)
|
Nominal Voltage Details
|
120v nominal output in battery mode
|
Communications Interface
|
USB (HID enabled)
|
Grounding Lug
|
Includes side panel grounding lug
|
Expandable Runtime
|
No
|
Assembly Required
|
No
|
Certifications & Standards
|
Energy Star
|
Maximum Operating Temperature
|
104°F (40°C)
|
Product Name
|
AVR 750VA Desktop UPS
|
Application/Usage
|
Printer, Home Theater, Home/Office, Router, TV, Digital Signage, Security System, ATM, Media Center, Computer, Blu-ray Player, Gaming Console
|
AVR
|
Yes
|
Alarm
|
Battery Backup, Low Battery, Overload, Replace Battery, Fault
|
Receptacle Detail
|
12 x NEMA 5-15R
|
Typical Battery Recharge Time
|
9 Hour
|
Energy Saving
|
Greater than 95% efficiency - GREEN UPS
|
Surge Energy Rating
|
316 J
|
AVR Range
|
Boost +18% / Buck -15%
|
Waveform Type
|
Pulse-width Modulated Sine Wave
|
Input Frequency
|
60 Hz
|
Plug/Connector Type
|
NEMA 5-15P
|
Product Series
|
AVR
|
Number of Battery & Surge Outlets
|
6
|
Package Contents
|
AVR 750VA Desktop UPS, USB cable, Instruction manual
|
Maximum Operating Elevation
|
10000 ft
|
DC System Voltage
|
12 V DC
|
Status Indicators
|
2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions
|
USB (HID Compliant) Port
|
Yes
|
EMI/RFI Noise Filter
|
Yes
|
Storage Temperature
|
5°F (-15°C) - 113°F (45°C)
|
USB
|
Yes
|
Number of Surge-only Outlets
|
6
|
Product Color
|
Black
|
Output Frequency
|
60 Hz
|
Replaceable Battery
|
Yes
|
Dataline Protection
|
RJ-11
|
Load Capacity
|
750 VA/450 W
|
Form Factor
|
Ultra-compact Desktop/Tower/Wall Mount
|
Package Includes
|
AVR750U 750VA 450W 120V Line-Interactive UPS with 12 Outlets;USB cable;Owner's manual
|
Grounding Details
|
Includes side panel grounding lug
|
UPS Dataline Suppression Details
|
Set of two 8 position RJ connectors protect either a single 10BaseT connection (pins 1,2,3 & 6; 7.5V clamping) or a single TEL/DSL connection (pins 4-5; 260V clamping)
|
Product Certifications
|
RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778
|
Product Compliance
|
FCC Part 15 Class A (USA)
|
Output Capacity (Watts)
|
450
|
Output Capacity (VA)
|
750
|
UPS Applications
|
Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality
|