Item
|
UPS System
|
UPS Type
|
Line Interactive
|
Power Rating
|
1.5 kVA
|
Mounting
|
Tower/Wall
|
Wattage
|
940 W
|
Input Voltage
|
120V AC
|
Output Voltage
|
115/120V AC
|
Backup Time (Half/Full Load)
|
13 min/4.5 min
|
Outlet Type
|
UPS/Surge
|
Medical Grade
|
No
|
Number of Outlets
|
8
|
Input Current
|
12 A
|
Phase
|
1
|
NEMA Plug Configuration
|
5-15p
|
Special Features
|
Hot Swappable Batteries
|
Green Environmental Attribute
|
Product Contributes To Reducing Energy Consumption
|
NEMA Receptacle Configuration
|
5-15R
|
Footnotes
|
USB and TEL/DSL
|
Includes
|
USB Cable and Phone Cable
|
Transfer Time
|
2 to 4 msec
|
Fax/Modem Line Protection
|
Yes
|
Automatic Volts Regulation
|
Yes
|
Ports
|
TEL/DSL, USB
|
Hz
|
60 Hz
|
Display Type
|
LED
|
Standards
|
UL 1778
|
Input Connection
|
NEMA 5-15P Plug
|
Battery Type
|
Valve Regulated Lead Acid (VRLA)
|
Internal UPS Replacement Battery Cartridge
|
RBC24-SLT
|
Individually Controllable Load Banks
|
No
|
Audible Alarm
|
Audible alarm indicates power-failure and low-battery conditions
|
Relative Humidity
|
0 to 95%, non-condensing
|
Battery Access
|
Battery access door
|
Output AC Waveform (AC Mode)
|
Sine wave
|
Rated input current (Maximum Load)
|
12A
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
UPS Input Connection Type
|
5-15P
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
|
Output Volt Amp Capacity (VA)
|
1500
|
Primary Form Factor
|
Tower
|
Expandable Battery Runtime
|
Extended runtime supported via optional external battery packs
|
Installation Form Factors Supported with Included Accessories
|
Tower
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
|
Alarm Cancel Operation
|
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
Output Voltage Regulation (Line Mode)
|
-18%, +8%
|
DC System Voltage (VDC)
|
24
|
UPS Certifications
|
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
|
High Availability UPS Features
|
Hot swappable batteries
|
Installation Form Factors Supported with Optional Accessories
|
Wallmount (UPSWM - tower mounting kit)
|
Battery Recharge Rate (Included Batteries)
|
Less than 4.5 hours from 10% to 90%
|
Communications Cable
|
USB cable included
|
Undervoltage Correction
|
Input voltages between 93 and 107 are boosted by 14%
|
Expandable Runtime
|
Yes
|
Output Watt Capacity (Watts)
|
940
|
Switches
|
2 Switches control off/on power status and alarm-cancel/self-test operation
|
UPS Output Receptacles (Surge Suppression Only)
|
6 UPS outlets, 2 surge-only outlets
|
Recommended Electrical Service
|
15A 120V
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V
|
Communications Interface
|
USB
|
Hot-Swap PDU options
|
PDUB15 (2U / 8 5-15R outlets)
|
LED Indicators
|
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
Output AC Waveform (Battery Mode)
|
PWM sine wave
|
Battery Mode BTU / Hr. (Full Load)
|
480
|
UPS Dataline Suppression
|
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
|
Overvoltage Correction
|
Input voltages between 128 and 147 are reduced by 12%
|
Low Voltage Transfer to Battery Power (Setpoint)
|
75
|
UPS Housing Material
|
Polycarbonate
|
Input Phase
|
Single-Phase
|
UPS AC Suppression Response Time
|
Instantaneous
|
Output kVA Capacity (kVA)
|
1.5
|
Output Receptacles
|
(8) 5-15R
|
WatchDog Compatibility
|
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Nominal Input Voltage(s) Supported
|
120V AC
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
UPS AC Suppression Joule Rating
|
690
|
Nominal Voltage Details
|
115v nominal output in battery mode
|
Cooling Method
|
Fan
|
External Battery Pack Compatibility
|
BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
AC Mode BTU / Hr. (Full Load)
|
356
|
Severe Undervoltage Correction
|
Input voltages between 75 and 92 are boosted by 30%
|
Frequency Compatibility
|
60 Hz
|
High Voltage Transfer to Battery Power (Setpoint)
|
147
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Battery Replacement Description
|
Hot-swappable, user replaceable batteries
|
Output Capacity Details
|
940W watts maximum when used with internal batteries or 1 BP24V15RT2U battery pack; Output is reduced to 600W maximum in all other external battery pack configurations
|
AC Mode Efficiency Rating (100% Load)
|
0.9
|
EMI / RFI AC Noise Suppression
|
Yes
|
Hot Swappable
|
Yes
|
Alarm
|
On Battery
|
Product Line
|
Omni
|
Certifications & Standards
|
UL1778 (USA), cUL (Canada), FCC Class B (emissions), NOM (Mexico), FCC Part 68 / Industry Canada (telecommunications)
|
Dataline Protection
|
RJ-45
|
Surge Energy Rating
|
480 J
|
Receptacle Detail
|
2 x NEMA 5-15R, 6 x NEMA 5-15R
|
Maximum Operating Temperature
|
122°F (50°C)
|
Typical Battery Recharge Time
|
4 Hour
|
Product Color
|
Black
|
Load Capacity
|
1500 VA/940 W
|
USB
|
Yes
|
Battery Life
|
6 Year
|
Assembly Required
|
No
|
Product Series
|
VS
|
Additional Information
|
OMNIVS1500XL Uninterruptible Power Supply offers voltage regulation, surge suppression and long lasting battery support, Supports entry level PCs up to 75 minutes during blackouts to enable shutdown without data loss, Regulates brownouts as low as 75 and overvoltages to 147V back to usable 120V nominal levels without using battery power, 6 UPS battery supported outlets, plus 2 additional surge suppression-only outlets, USB port and cable enables UPS monitoring and unattended shutdown in the case of extended power failure, PowerAlert software available via free download from www.tripplite.com, Dataline surge suppression protects standard dialup/DSL or ethernet line connection, Audible alarm and 4 front panel LEDs offer complete UPS and line power status information, 1500VA power handling ability supports a variety of sensitive electronic equipment, 5 minutes full load runtime (1500VA), 14 minutes half load runtime (750VA), Runtime is further expandable with the addition of BP24V14 external battery pack, Supports hot swappable battery replacement via built-in access panel, $200,000 connected equipment insurance (USA & Canada Only), 2 year warranty
|
Package Contents
|
OMNIVS1500XL Line Interactive UPS, USB and telephone cable, User manual with warranty information
|
Product Name
|
8-Outlet UPS Power Protection System
|
Form Factor
|
Tower
|
Status Indicators
|
4 front panel LEDs indicate line power status, battery power status, battery low/replace status and voltage regulation operation
|
Plug/Connector Type
|
NEMA 5-15P
|
Product Compliance
|
FCC Part 15 Class B (USA)
|
UPS Applications
|
Home/Office Desktop; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality
|
Output Capacity (Watts)
|
940
|
Product Certifications
|
CSA (Canada); NOM (Mexico); UL 1778
|
Output Capacity (VA)
|
1500
|
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
|
480
|
Package Includes
|
OMNIVS1500XL Line Interactive UPS;USB and telephone cable;Owner's manual with warranty information
|