Item
|
UPS System
|
UPS Type
|
Line Interactive
|
Power Rating
|
1 kVA
|
Mounting
|
Rack
|
Wattage
|
800 W
|
Input Voltage
|
120V AC
|
Output Voltage
|
120V AC
|
Backup Time (Half/Full Load)
|
15 min/5.3 min
|
Outlet Type
|
UPS/Surge
|
Medical Grade
|
No
|
Number of Outlets
|
6
|
Automatic Volts Regulation
|
Yes
|
Ports
|
EPO, RS232, Slot for SNMPWEBCARD, USB
|
Hz
|
60 Hz
|
NEMA Plug Configuration
|
5-15p
|
Green Environmental Attribute
|
Product Contributes To Reducing Energy Consumption
|
Footnotes
|
Slot for SNMPWEBCARD
|
Includes
|
PowerAlert Software, Serial and EPO Cables and 4-Post Rackmount Installation Kit, USB
|
NEMA Receptacle Configuration
|
5-15R
|
Display Type
|
LCD
|
Transfer Time
|
2 to 4 msec
|
Input Current
|
9.2 A
|
Special Features
|
Hot Swappable Batteries
|
Standards
|
UL 1778
|
Phase
|
1
|
Fax/Modem Line Protection
|
No
|
Input Connection
|
NEMA 5-15P Plug
|
Battery Type
|
Valve Regulated Lead Acid (VRLA)
|
Nominal Output Voltage(s) Supported
|
110V; 115V; 120V
|
Audible Noise
|
45 dBA maximum, front side 1m
|
Output AC Waveform (Battery Mode)
|
Pure Sine wave
|
Grounding Lug
|
Back panel grounding lug
|
Rated input current (Maximum Load)
|
9.2A
|
Operating Temperature Range
|
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Installation Form Factors Supported with Optional Accessories
|
2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
|
AC Mode BTU / Hr. (Full Load)
|
134
|
Load Management Receptacles
|
Two switchable two-outlet 5-15R load banks
|
Network Management Cards
|
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX
|
Frequency Compatibility
|
60 Hz
|
Battery Recharge Rate (Included Batteries)
|
Less than 4 hours from 10% to 90% (typical, full load discharge)
|
Expandable Runtime
|
No
|
Network Monitoring Port Description
|
Supports detailed monitoring of UPS and site power conditions
|
Output Watt Capacity (Watts)
|
800
|
Power Factor
|
0.8
|
Low Voltage Transfer to Battery Power (Setpoint)
|
83
|
Output Voltage Regulation (Line Mode)
|
-21%, +8%
|
Individually Controllable Load Banks
|
Yes
|
High Voltage Transfer to Battery Power (Setpoint)
|
147
|
Output AC Waveform (AC Mode)
|
Sine wave
|
Output Voltage Regulation (Battery Mode)
|
+/- 5%
|
Included Mounting Accessory Description
|
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
Storage Temperature Range
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
Alarm Cancel Operation
|
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
|
Battery Mode BTU / Hr. (Full Load)
|
600
|
Switches
|
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
|
Overvoltage Correction
|
Input voltages between 128 and 147 are reduced by 12%
|
Output kVA Capacity (kVA)
|
1
|
Relative Humidity
|
0 to 95%, non-condensing
|
WatchDog Compatibility
|
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Input Phase
|
Single-Phase
|
Communications Interface
|
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
|
Internal UPS Replacement Battery Cartridge
|
Current version uses RBC24V-LCD ; Prior versions used RBC92-2U ; Check the label inside the battery door to verify the appropriate replacement battery part number
|
Output Volt Amp Capacity (VA)
|
1000
|
Recommended Electrical Service
|
15A 120V
|
UPS AC Suppression Joule Rating
|
570
|
Nominal Voltage Details
|
120v nominal output in battery mode
|
Voltage Regulation Description
|
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
|
Audible Alarm
|
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
|
EMI / RFI AC Noise Suppression
|
Yes
|
Output Receptacles
|
(6) 5-15R
|
UPS Certifications
|
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
|
UPS Input Connection Type
|
5-15P
|
High Availability UPS Features
|
Hot swappable batteries
|
UPS Housing Material
|
Steel
|
Installation Form Factors Supported with Included Accessories
|
4 post 19 inch rackmount
|
Input Circuit Breakers
|
15A
|
Primary Form Factor
|
Rackmount
|
Network UPS Tools Compatibility
|
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
|
Cold Start (Startup in Battery Mode During a Power Failure)
|
Cold-start operation supported
|
Cooling Method
|
Fan
|
Front Panel LCD Display
|
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
|
Undervoltage Correction
|
Input voltages between 83 and 107 are boosted by 14%
|
Battery Access
|
Front panel battery access door
|
PowerAlert Software
|
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
|
Battery Replacement Description
|
Hot-swappable, user replaceable batteries
|
AC Mode Efficiency Rating (100% Load)
|
0.95
|
Communications Cable
|
USB and DB9 cabling included
|
Nominal Input Voltage(s) Supported
|
120V AC
|
DC System Voltage (VDC)
|
24
|
UPS AC Suppression Response Time
|
Instantaneous
|
Waveform Type
|
Sine Wave
|
Network Management
|
SNMP Manageable
|
Receptacle Detail
|
6 x NEMA 5-15R
|
Typical Battery Recharge Time
|
4 Hour
|
Plug/Connector Type
|
NEMA 5-15P
|
Total Number of Expansion Slots
|
1
|
Load Capacity
|
1000 VA/800 W
|
Battery Chemistry
|
Lead Acid
|
Software Included
|
PowerAlert Software
|
Certifications & Standards
|
UL1778 (USA), cUL (Canada), FCC Class B (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications
|
Product Name
|
SMART1000RM2U UPS System
|
USB
|
Yes
|
Emergency Power OFF
|
Yes
|
Hot Swappable
|
Yes
|
Alarm
|
Low Battery, Overload, On Battery
|
Product Line
|
SmartPro
|
Maximum Operating Temperature
|
104°F (40°C)
|
Package Contents
|
SMART1000RM2U UPS System, PowerAlert Software CD, Serial & EPO Cabling, 4 x Post Rackmount Installation Kit, Instruction Manual
|
UPS Applications
|
Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality
|
Output Capacity (Watts)
|
800
|
Product Certifications
|
CSA (Canada); NOM (Mexico); UL 1778
|
Package Includes
|
SMART1000RM2U SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS;USB cable;DB9 cable;EPO cable;Mounting hardware;Owner's manual
|
Grounding Details
|
Back panel grounding lug
|
Output Capacity (VA)
|
1000
|
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
|
600
|
Product Compliance
|
FCC Part 15 Class B (USA)
|