Item
|
Overload Module
|
Overload Relay Amp Setting
|
1.25 to 5 A
|
Coil Volts
|
110 to 240V AC; 110 to 220V DC
|
Number of Poles
|
3
|
Features
|
Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Manual reset; Earth fault protection; Free of Halogen, Mercury & Pvc; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration
|
Standards
|
CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1
|
Hz
|
40 to 60 Hz
|
Frame / Series / Class / Code
|
Class 10
|
Trip Class - Overload
|
10
|
Separate Mounting
|
No
|
Kit Required for Retrofit Mtg.
|
No
|
Use With - Contactors and Starters
|
Mfr. Series LUA1C Contactors
|
Sensing Method
|
Thermal
|
Reset Type - Relay
|
Manual
|
Item - Relay
|
IEC Style Overload Relay
|
Overload Relay Current Range
|
1.25 to 5A
|
Operating Voltage
|
690V AC
|
Weight
|
0.135 kg
|
Trip Class
|
10
|
Maximum Rated Motor Current Adjustment
|
5 A
|
Reset Type
|
Manual
|
Maximum Operating Temperature
|
158 Degrees F
|
Maximum Voltage Rating
|
690V AC
|
Compatible with Series
|
TeSys Ultra
|
Minimum Operating Temperature
|
-13 Degrees F
|
Minumum Rated Motor Current Adjustment
|
1.25 A
|
Coil Voltage
|
110-220V DC, 110-240V AC
|
Phase
|
Three
|
Compatible with Manufacturer Model Number
|
LUB12, LUB32, LUB38
|
Compatible Manufacturer Part Number
|
LUB12, LUB32, LUB38
|
Compatible Manufacturer Model Number
|
LUB12, LUB32, LUB38
|
For Use with Mfr. Model Number
|
LUB12, LUB32, LUB38
|
For Use With Mfr. Model Number
|
LUB12, LUB32, LUB38
|
Fixing Mode
|
Plug-in front face)
|
Vibration Resistance
|
2 gn 5 to 300 Hz power poles open IEC 60068-2-6; 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
|
Ambient Air Temperature For Storage
|
-40 to 185°F (-40 to 85°C)
|
Rated Impulse Withstand Voltage
|
6 kV IEC 60947-6-2
|
Product Certifications
|
CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
|
Product Or Component Type
|
Standard control unit
|
Shock Resistance
|
10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27
|
Rated Insulation Voltage
|
690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
|
Resistance To Fast Transients
|
2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4
|
Immunity To Voltage Dips
|
70% / 500 ms IEC 61000-4-11
|
Typical Current Consumption
|
280 mA 110 to 240 V AC I maximum while closing with LUB12; 280 mA 110 to 240 V AC I maximum while closing with LUB32; 280 mA 110 to 240 V AC I maximum while closing with LUB38; 280 mA 110 to 220 V DC I maximum while closing with LUB12; 280 mA 110 to 220 V DC I maximum while closing with LUB32; 280 mA 110 to 220 V DC I maximum while closing with LUB38; 35 mA 110 to 240 V AC I rms sealed with LUB12; 25 mA 110 to 240 V AC I rms sealed with LUB32; 25 mA 110 to 240 V AC I rms sealed with LUB38; 35 mA 110 to 220 V DC I rms sealed with LUB12; 25 mA 110 to 220 V DC I rms sealed with LUB32; 25 mA 110 to 220 V DC I rms sealed with LUB38
|
Main Function Available
|
Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Manual reset; Earth fault protection
|
Utilisation Category
|
AC-44; AC-41; AC-43
|
Operating Time
|
35 ms opening with LUB12 control circuit; 35 ms opening with LUB32 control circuit; 35 ms opening with LUB38 control circuit; 50 ms closing with LUB12 control circuit; 50 ms closing with LUB32 control circuit; 50 ms closing with LUB38 control circuit
|
Rated Operational Voltage
|
690 V AC
|
Protective Treatment
|
TH IEC 60068
|
Heat Dissipation
|
2 W control circuit with LUB12; 3 W control circuit with LUB32; 3 W control circuit with LUB38
|
Load Type
|
3-phase motor self-cooled
|
Control Circuit Voltage Limits
|
88 to 264 V AC 110 to 240 V in operation; 88 to 242 V DC 110 to 220 V in operation; 55 V AC 110 to 240 V drop-out; 55 V DC 110 to 220 V drop-out
|
Control Circuit Voltage
|
110 to 240 V AC; 110 to 220 V DC
|
Thermal Overload Class
|
Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2; Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
|
Product Specific Application
|
Basic protection requirements for motor starters: overload and short-circuit
|
Ambient Air Temperature For Operation
|
-13 to 158°F (-25 to 70°C)
|
Product Compatibility
|
Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12FU; Reversing contactor breaker LU2B32FU; Reversing contactor breaker LU2B38FU
|
Immunity To Radioelectric Fields
|
10 V IEC 61000-4-6
|
Fire Resistance
|
1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12
|
Phase Failure Sensitivity
|
Yes
|
Non-Dissipating Shock Wave
|
1 kV serial mode IEC 60947-6-2; 2 kV common mode IEC 60947-6-2
|
Tripping Threshold
|
14.2 x Ir +/- 20%
|
Compatibility Code
|
LUCA
|
Resistance To Electrostatic Discharge
|
8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2
|
Resistance To Radiated Fields
|
9.14 V/m (10 V/m) 3 IEC 61000-4-3
|
Device Application
|
Motor control; Motor protection
|
IP Degree Of Protection
|
IP20 front panel and wired terminals IEC 60947-1; IP20 other faces IEC 60947-1; IP40 front panel outside connection zone IEC 60947-1
|
Immunity To Microbreaks
|
3 ms
|
Operating Altitude
|
6561.68 ft (2000 m)
|
Motor Power KW
|
1.5 kW 400 to 440 V AC 50/60 Hz; 2.2 kW 500 V AC 50/60 Hz; 3 kW 690 V AC 50/60 Hz
|
Safe Separation Of Circuit
|
400 V SELV between the control and auxiliary circuits IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
|