36 Results for Output Load Reactors by KDR-LINE REACTORS
KDR-LINE REACTORS
Key Features:
- Watts Loss: 105 W
- Height: 6
- Width: 7.2
Key Features:
- Width: 9
- Filter Type: Ultra Low Z
- Impedance: 1.5 %
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Standards: RoHS, UL Listed
- Enclosure: Open
Key Features:
- Item: Output Reactor
- Depth: 11
- Impedance: 1.5 %
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Enclosure: Open
- Depth: 9.75
Key Features:
- Depth: 4.25
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Standards: UL Listed
Key Features:
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
- Depth: 7.5
- Input Voltage: 575V AC
Key Features:
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
- Filter Type: Ultra Low Z
- Height: 5.75
Key Features:
- Filter Type: Ultra Low Z
- Max. Output Amps: 77 A
- Depth: 6
Key Features:
- Max. HP: 75 hp
- Item: Output Reactor
- Phase: Three
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Filter Type: Ultra Low Z
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
Key Features:
- Width: 11
- Watts Loss: 280 W
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
Key Features:
- Phase: Three
- Max. Output Amps: 22 A
- Depth: 4.25
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Watts Loss: 123 W
- Max. Output Amps: 52 A
Key Features:
- Max. Output Amps: 99 A
- Phase: Three
- Max. HP: 100 hp
Key Features:
- Width: 15
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Impedance: 1.5 %
Key Features:
- Input Voltage: 480V AC
- Standards: UL Listed
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
Key Features:
- Phase: Three
- Enclosure: Open
- Filter Type: Ultra Low Z
Key Features:
- Height: 9
- Features: Protects 6-Pulse Rectifiers and Power Conversion
- Filter Type: Ultra Low Z
Key Features:
- Filter Type: Ultra Low Z
- Standards: RoHS, UL Listed
- Enclosure: Open
Key Features:
- Standards: RoHS, UL Listed
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Enclosure: Open
Key Features:
- Depth: 9.31
- Impedance: 1.5 %
- Enclosure: Open
Key Features:
- Height: 9
- Features: Protects 6-Pulse Rectifiers and Power Conversion
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
Key Features:
- Standards: RoHS, UL Listed
- Watts Loss: 465 W
- Filter Type: Ultra Low Z
Key Features:
- Item: Output Reactor
- Watts Loss: 254 W
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
Key Features:
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Max. Output Amps: 180 A
Key Features:
- Input Voltage: 575V AC
- Max. HP: 450 hp
- Enclosure: Open
Key Features:
- Item: Output Reactor
- Width: 9
- Phase: Three
Key Features:
- Item: Output Reactor
- Filter Type: Ultra Low Z
- Impedance: 1.5 %
Key Features:
- Depth: 4.25
- Max. Output Amps: 17 A
- Impedance: 1.5 %
Key Features:
- Item: Output Reactor
- Enclosure: Open
- Standards: RoHS, UL Listed
Key Features:
- Max. Output Amps: 32 A
- Item: Output Reactor
- Watts Loss: 106 W
Key Features:
- Filter Type: Ultra Low Z
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Standards: RoHS, UL Listed
Key Features:
- Features: Protects 6-Pulse Rectifiers and Power Conversion
- Phase: Three
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
Key Features:
- Input Voltage: 575V AC
- Standards: UL Listed
- Max. HP: 25 hp
Key Features:
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Watts Loss: 587 W
About Output Load Reactors
Noise spikes (AKA harmonic distortion) can ride on the leading edge of electrical signals from a VFD’s high frequency PWM three-phase output to the motor. An output load reactor serves as a buffer between the VFD and the motor, providing an increase in inductance along the cable run, thereby protecting the electrical motor from those spikes. If the wiring distance between the VFD and the motor is not very long, use an output line reactor instead.